A 2 hp three phase delta connected motor operates at a power factor of 0.8 (lagging). The motor has an efficiency of 82%. If the motor is connected to a 3 phase supply of line to line voltage of 400 V, calculate the line current and phase current of the motor. - E Tips BD

Post Top Ad

Wednesday, June 19, 2019

A 2 hp three phase delta connected motor operates at a power factor of 0.8 (lagging). The motor has an efficiency of 82%. If the motor is connected to a 3 phase supply of line to line voltage of 400 V, calculate the line current and phase current of the motor.


A 2 hp three phase delta connected motor operates at a power factor of 0.8  (lagging).  The  motor  has  an  efficiency  of  82%.  If  the  motor  is  connected  to  a  3  phase  supply of line to line voltage of 400 V, calculate the line current and phase current of the motor.

Solution:
Output power of the motor (mechanical), Pout= 2 hp = 2 x 746 W = 1492 W
Efficiency, η= 0.82
So, input power (electrical), Pin= P = Pout / η= 1819.5 W
Power factor, cosθ= 0.8

Now,  P = √3VL IL cosθ

IL = P/√3VL cosθ  = 1819.5/√3x400x0.8 = 3.28A

For a delta connected system, Ip =  IL/√3 = 1.9A


EEE Job Math-2
Any complain/find wrong/feedback of this post, Plese inform us: etipsbdinfo@gmail.com
Please share the post link to your Facebook/twitter.


No comments:

Post a Comment

Post Top Ad